메뉴 바로가기

본문으로 바로가기

Home / Compare cell counters / Compare cell counters

Compare cell counters

NanoEntek’s Compare cell counters

  •  

    ADAM-MC2

    ADAM-CellT

    ADAM-SCC2

    EVE PLUS

    Arthur

    ADAM™ MC Plus

     

    EVE™ HT FL

    EVE™ HT

    ADAMII™ LS

  • Spec

    Analysis Time

    Focus

    Stain

    Optic

    Measuring Vol (μL)

    Measuring Range
    (cell/mL)

     

    < 13sec

    Auto

    PI(Propidium lodide)

    Fluorescence

    3.4

    5x10^4-4x10^6

     

    < 13sec

    Auto

    PI(Propidium lodide)

    Fluorescence

    3.4

    5x10^4-4x10^6

     

    < 13sec

    Auto

    PI(Propidium lodide)

    Fluorescence

    3.4

    0.05-1.15x10^6

     

    < 1sec

    Auto & Manual

    Trypan blue

    Bright

    0.41

    1x10^4-2x10^7

     

    < 40 sec / test (4ch)

    Auto

    AO/DAPI, PI

    Fluorescence

    3.2

    5x10^4~2x10^7

     

    3 ~ 6minutes / 48 tests

    Auto

    Trypan blue, AO/DAPI

    Fluorescence

    -

    1x10^4-2x10^7

     

    < 3 min / 48 tests

    Auto

    Trypan blue

    Bright

    -

    1x10^4-2x10^7

     

    2 min–4 min 30 sec

    Auto

    AO/DAPI, PI

    Bright & Fluorescence (GFP/RFP/DAPI)

    ≤7.8µL

    5x10^4-5x10^6

  • Cell type

    Cell line, PBMCs,
    Stem cell, WBC,
    CAR-T cell

    Cell line, PBMCs,
    Stem cell, WBC,
    CAR-T cell

    Somatic cell

    Cell line
    (clumpy cell, single cell)

    Cell line
    (clumpy cell, single cell)

    PBMC, Stem cell,
    Primary cell, Cell line, Splenocyte

    PBMC, Stem cell,
    Primary cell, Cell line

    Cell line

    Cell line,
    Primary cell, PBMC, Adipose Stem cell

  • Function

    Total cell count, Viability
    Cell size, Quality control

    Total cell count,
    Viability Cell size,
    21 CFR part 11,
    Quality control

    Total cell count,
    Cell size, Quality control

    Total cell count,
    Viability, Cell size

    Total cell count,
    Viability, Cell size,
    Apoptosis, Cell cycling,
    growth curve,
    Transfection efficiency

    Total cell
    counting, viability,
    Cell aggregation ratio,
    Cell size

    Total cell,
    Live/Dead Cell, Viability,
    Cell Size, 21 CFR part 11,
    Count clumpy cells

    Total cell, Viability,
    Cell Size, 21 CFR part 11,
    Count clumpy cells
    and irregular-shaped cells

    Total cell, Viability,
    Cell Size, 21 CFR part 11,
    Apoptosis, Cell cycle,
    Dot plot

  • Disposable
    chip
  • Brochure